Specification
| Operating Voltage | 10-30Vdc or 5V optional, polarity protection |
| Current Consumption | < 110mA (24V power supply) no load |
| Output Signal | RS485, you can set the length, angle, speed application output |
| Output load capacity | ≤ 400 ohms, the standard 200-250 Ohm work |
| Resolution | 12 bits to 16 bits |
| Operating Temperature | -40—75℃ Programming temperature range:0℃~+70℃ |
| Storage Temperature | -40—80℃ |
| Protection class | IP67 for housing IP65 for shaft |
| Vibration & shock | 20g,10~2000Hz;100g,6ms |
| Permissible Rotation Rate | 2400rpm |
| Output refresh cycle | <1.4ms |
| Connection Cable | 1m 8-core shielded cable. |
| Overall Feature | Clamping flange or synchronous flange, metal enclosure, sealed dual-bearing structure ( see attached drawing of overall dimension) |
| Signal Conditioning | direction can be set; preset position, external set, such as external zero |
Instance
Read data
Host send: D + address + 0D
Encoder reply: X + address +> + match bit + data bit + 0D
Example:
Host send: 44 30 31 0D (when the encoder address is 01)
Encoder back: 58 30 31 3E 2B 30 30 30 30 30 30 30 31 32 33 0D
Encoder reset command:
Host send: D + address + L + M + sum check + 0D
Encoder reply: X + address + l + m + sum check + 0D
Example:
Host send: 44 30 31 4C 4D sum check 0D (when the encoder address is 01)
Encoder reply: 58 30 31 6C 4D sum check 0D (reset current position)
Installation dimensions (mm)
Clamping flange (default)

synchro flange

Blind hollow shaft