PRODUCT DESCRIPION
Product
|
Unit cooler/cold room evaporartor
|
Model
|
DD-8.0/40
|
Refrigerant
|
R404A
|
Cooling Capacity
|
8KW
|
Cooling Consumption Power
|
3.91KW
|
Cooling area
|
40㎡
|
Fan Diameter
|
400mm
|
Fan Quantity
|
2
|
Fan Motor Voltage
|
380V / 50HZ / 3PH
|
Fan Volume
|
2*4000 m³/h
|
Fan motor power
|
2*230W
|
Size
|
1750x500x550 mm
|
Connection Pipe Inlet Diameter
|
16mm
|
Connection Pipe Outlet Diameter
|
25mm
|
Evaporation tube outer diameter
|
14.5mm
|
Package
|
wooden case
|

* Electric heating tube defrosting air cooler overview and use
Electric heating tube defrosting air cooler is a kind of cooling facility, which matches with freon system condensing unit requires quick defrost. Based on different temperature cold room, the series can be divided into three types,DLS,DDS,DJS.
DLS series can apply to cold room, in which temperature is around 0 ℃.
DDS series is freezer room air cooler, the cold
room temperature is around -18℃.
room temperature is around -18℃.
DJS series is blast freezer air cooler, the cold room temperature is below -25℃.

Real Shot Show