Vietnamese Chinese (Traditional) English Japanese Korean

Bộ lọc dùng cho phòng khí nén

Filter Regulator with Built-in Pressure Gauge AWG

 

Series/CAD Air flow capaciy L/min (ANR) Port size
AMG 300 to 12000 1/8 to 2
Features

Compressed air without water can be obtained.

Water drop removal ratio: 99%

 

Main Line Filter AFF

Series/CAD Filtration (μm) Air flow L/min (ANR) Port size
AFF 3 (Filtration efficiency 99%) 300 to 42000 1/8 to 4B flange
Features

Can remove impurities such as oil, water and foreign matter in compressed air. It improves the function of the ownward dryer, extends the life of the precision filter, and prevents trouble with the equipment.

 

Mist Separator AM

Series/CAD Filtration (μm) Air flow L/min (ANR) Port size
AM 0.3
(Filtration efficiency 99.9%)
300 to 12000 1/8 to 2
Features

Can separate and remove oil mist and remove solid particles such as rust or carbon of 0.3 μm or larger.

 

Micro Mist Separator AMD

Series/CAD Filtration (μm) Air flow L/min (ANR) Port size
AMD 0.01
(Filtration efficiency 99.9%)
200 to 40000 1/8 to 6B flange
Features

Can separate and remove aerosol state oil mist and remove carbon or dust of 0.01 μm or larger.

Should be used as a prefilter of compressed air for precision instruments or clean room requiring high levels of clean air.

 

Micro Mist Separator with Pre-filter AMH

Series/CAD Filtration (μm) Air flow L/min (ANR) Port size
AMH 0.01
(Filtration efficiency 99.9%)
200 to 12000 1/8 to 2
Features

Integrates Series AM and Series AMD to achieve a reduction in installation space and to reduce piping installation labor and costs.

Can separate and remove aerosol state oil mist and remove carbon or dust of 0.01 μm or larger.

Should be used as a prefilter of compressed air for precision instruments or clean room requiring high levels of clean air.

 

Super Mist Separator AME

Series/CAD Filtration (μm) Air flow L/min (ANR) Port size
AME 0.01
(Filtration efficiency 99.9%)
200 to 12000 1/8 to 2
Features

Can separate and absorb aerosol state fine oil particles and change the oil lubricating compressed air to oilless equivalent air.

Should be applied for filtration of compressed air requiring a high degree cleanliness such as the compressed air for coating lines, for clean rooms and for equipment that must avoid oils.

 

Odor Removal Filter AMF

Series/CAD Filtration (μm) Air flow L/min (ANR) Port size
AMF 0.01
(Filtration efficiency 99.9%)
200 to 40000 1/8 to 2
Features

Efficiently removes odors in compressed air with an activated carbon element. The unit is designed for clean rooms where odors must be removed.

Activated carbon element with large filtration area.

Easy replacement and installation of elements.

 

Clean Gas Filter SF

Series/CAD Type Operating pressure Filtration
SFA100/200/300 Cartridge type disc Max.1.0 MPa
(Vacuum: 1.3 x 10-6 kPa)
0.01 μm
(Filtration efficiency 99.99%)
SFB100 Cartridge type straight Max.1.0 MPa
(Vacuum: 1.3 x 10-6 kPa)
Features

Cartridge type allows element replacement.

SFB300 Disposable type straight Max.15 MPa
(Vacuum: 1.3 x 10-6 kPa)
0.01 μm
(Filtration efficiency
99.99%)
SFC100 Disposable type
multiple disc
Max.1.8 MPa
(Vacuum: 1.3 x 10-6 kPa)
Features

Compact disposable type for semiconductor industry

 

Clean Air Filter/Hollow Fiber Element SFD

Series/CAD Type Operating pressure Filtration
SFD100 Disposable type
(Irreplaceable element)
MAX.1.0 MPa 0.01 μm
(Filtration efficiency 99.99%)
SFD200 Cartridge type
(Replaceable element)
Features

Built-in hollow fiber element

Pressure drop: 0.03 MPa (Inlet pressure 0.7 MPa, Max. flow rate)

Conforms to RoHS reduction of environmentally detrimental chemicals.

 

Clean Air Module LLB

Series/CAD Fluid Set pressure Flow range L/min (ANR)
LLB3 Clean air
N2gasNOTE
0.05 to 0.4 MPa 5 to 100
LLB4 50 to 500
Features

Clean equipment modularized (Reduction of piping labor/Space-saving)

Clean air is easily available.

Nominal filtration rating: 0.01 μm (Filtration efficiency 99.99%)

Wetted parts: Grease-free, Silicon-free

Assembled in a clean room, shipped and packed in a duplicate package

24 combinations available

 

Auto Drain Valve AD

Model/CAD Port size Drain discharge port size
AD402 1/4,3/8,1/2 3/8
AD600 3/4,1 3/4,1
Features

Drainage is automatically discharged.

 

Motor Operated Auto Drain ADM

Model/CAD Power consumption (W) Port size
ADM200 4 IN 3/8,1/2
OUT 3/8
Features

Reliably discharges even highly viscous drainage.

 

Heavy Duty Auto Drain ADH

Model/CAD Port size Auto drain
ADH4000 1/2 Float type
Features

Easy maintenance.

Possible to maintain easily without removing pipes.

No need for electric power and no waste of air.

Float style drain allows automatic draining without electric power.

 

Differential Pressure Gauge GD40

Model/CAD Accuracy Scale range
GD40 ±0.006 MPa 0 to 0.2 MPa
Features
  • The pressure differential at the inlet and the outlet of compressed air equipment can be viewed at a glance on the pressure differential gauge.
  • It is ideal for the maintenance control of filters.
  • Can be installed easily by merely providing a bypass circuit.
  • Provided with a protective cover to prevent hazards.