Electronic Pressure Switches/Sensors (Sensor/Amplifier Integrated Type)
|
3-Screen Display High-Precision Digital Pressure Switch ZSE20(F)/ISE20
・Visualization of setting items
・Simple 3 step setting ・Easy screen switching Setting is possible while checking the measured value. ・Delay time: Fastest 1.5 ms or less ・Current consumption: 25 mA or less |
|
Other Data |
---|
Series | Type | Rated pressure range |
---|---|---|
ZSE20F | Compound pressure | −100.0 to 100.0kPa |
ZSE20 | Vacuum pressure | 0.0 to −101.0kPa |
ISE20 | Positive pressure | −0.100 to 1.000MPa |
|
2-Color Display High-Precision Digital Pressure Switch ZSE30A(F)/ISE30A
・With one-touch fitting (Straight, Elbow)
・Space-saving, capable of vertical and horizontal contact mounting ・With display calibration function ・Simultaneous copying is possible for maximum 10 units. Click here for the digital switch setting system |
|
Other Data |
---|
Series | Type | Rated pressure range |
---|---|---|
ZSE30AF | Compound pressure | -100.0 to 100.0kPa |
ZSE30A | Vacuum pressure | 0.0 to -101.0kPa |
ISE30A | Positive pressure | -0.100 to 1.000MPa |
|
2-Color Display High-Precision Digital Pressure Switch ZSE40A(F)/ISE40A
・IP65
・Applicable fluid: Air, Non-corrosive gas, Non-flammable gas ・Simultaneous copying is possible for maximum 10 units. ・3-step setting ・With One-touch fitting Click here for the digital switch setting system |
|
Other Data |
---|
Series | Type | Rated pressure range |
---|---|---|
ZSE40AF | Compound pressure | -100.0 to 100.0kPa |
ZSE40A | Vacuum pressure | 0.0 to -101.3kPa |
ISE40A | Positive pressure | -0.100 to 1.000MPa |
|Compact Digital Pressure Switch ZSE10(F)/ISE10
・Low profile 9.8 mm
・Vertical mounting space reduced to approx. 1/2 (Compared to ZSE/ISE30A series) ・Simultaneous copying is possible for maximum 10 units. ・3-step setting |
|
Other Data |
---|
Series | Type | Rated pressure range |
---|---|---|
ZSE10F | Compound pressure | -100.0 to 100kPa |
ZSE10 | Vacuum pressure | 0.0 to -101.0kPa |
ISE10 | Positive pressure | -0.100 to 1.000MPa |
|2-Color Display Digital Pressure Switch ISE70/75(H)
・Metal body type (Aluminum die-casted)
・IP67 ・With M12 connector |
|
Other Data |
---|
Series | Type | Rated pressure range |
---|---|---|
ISE70 | Positive pressure (For air) | 0 to 1MPa |
ISE75 | Positive pressure (For general purpose fluids) | 0 to 10MPa |
ISE75H | Positive pressure (For general purpose fluids) | 0 to 15MPa |
|2-Color Display Digital Pressure Switch ZSE/ISE80
・Suitable for a wide variety of fluids with stainless diaphragm
・IP65 ・RoHS compatible ・Low leakage. VCR®, Swagelok® compatible fittings can be selected. ・Back piping, underside piping Click here for the digital switch setting system |
|
Other Data |
---|
Series | Type | Rated pressure range |
---|---|---|
ZSE80F | Compound pressure | -100.0 to 100.0kPa |
ZSE80 | Vacuum pressure | 0.0 to -101.0kPa |
ISE80 | Positive pressure | -0.100 to 1.000MPa |
ISE80H | Positive pressure | -0.100 to 2.000MPa |
|LCD Readout Digital Pressure Switch ZSE/ISE3
・Built-in failure prediction output function.
・Can be integrated with a vacuum unit, Series ZX. ・Suction filter comes as standard. |
|
Other Data |
---|
Series | Type | Set pressure range |
---|---|---|
ZSE3 | Vacuum pressure | 0 to -101kPa |
ISE3L | Positive pressure | 0 to 98kPa |
ISE3 | Positive pressure | 0 to 0.98MPa |
|Compact Pressure Switch ZSE/ISE1
・Can be integrated with ZM ejector system.
|
|
Other Data |
---|
Series | Type | Set pressure range |
---|---|---|
ZSE1 | Vacuum pressure | 0 to -101kPa |
ISE1L | Positive pressure | 0 to 100kPa |
ISE1 | Positive pressure | 0 to 1MPa |
|Compact Pressure Switch ZSE/ISE2
・Can be integrated with ZX or ZR ejector system.
・Suction filter comes as standard. |
|
Other Data |
---|
Series | Type | Set pressure range |
---|---|---|
ZSE2 | Vacuum pressure | 0 to -101kPa |
ISE2L | Positive pressure | 0 to 100kPa |
ISE2 | Positive pressure | 0 to 1MPa |
|Air Checker: Electronic Pressure Switch PS1000/1100/1200
・Plug-in port for One-touch fittings.
・With LED light. |
|
Other Data |
---|
Series | Type | Set pressure range |
---|---|---|
PS1000 | Positive pressure | -0.1 to 0.45MPa |
PS1100 | For vacuum/residual pressure | -0.1 to 0.4MPa |
PS1200 | For vacuum | -100 to 0kPa |
|3-Color Display Digital Gap Checker ISA3
・Check at a glance if the workpiece is placed or not
・The clearance distance between the detection surface and the workpiece can be found intuitively. ・Simple Setting: Setting is possible while checking the displayed value ・Energy Saving: Air consumption 60% reduction ・Improved drainage resistance: 10 times or more |
|
Other Data |
---|
Series | Rated distance range | Piping specification Supply side | Piping specification Detection side |
---|---|---|---|
ISA3-F | 0.01 to 0.03 mm | Rc, G 1/8 | φ4, φ6 One-touch fitting, G 1/8 |
ISA3-G | 0.02 to 0.15 mm | Rc, G 1/8 | φ4, φ6 One-touch fitting, G 1/8 |
ISA3-H | 0.05 to 0.30 mm | Rc, G 1/8 | φ4, φ6 One-touch fitting, G 1/8 |
|
Non-Contact Sensor for Workpiece Placement Confirmation/Air Catch Sensor ISA2
・Gap detection
・Can be configured with a regulator and 2 port solenoid valve. ・With LED level meter ・Plug connector. Easy to add and remove manifold stations. |
|
Other Data |
---|
Series | Detection range | Recommended nozzle dia. |
---|---|---|
ISA2 | 0.01 to 0.25 mm | φ1.5 |
ISA2 | 0.03 to 0.50 mm | φ2.0 |
|Digital Pressure Switch (Built-in Regulator Type) ISE35
・Modular type mountable
・Series ARM10/11 mountable ・Selectable pressure unit ・With anti-chattering function ・Power-saving mode |
|
Other Data |
---|
Series | Type | Recommended nozzle dia. |
---|---|---|
ISE35 | Positive pressure | -0.1 to 1MPa |